Safety Devices (EN 730 and ISO 5175)

for cylinder-regulators and tapping points
Type DS 1000 and Type DS 2000 with pressure sensitive gas cut of

 

Highlights

  • Dust filter promotes long life
  • Gas non-return valve prevents dangerous gas mixtures
  • Flame arrestor prevents flashback
  • Thermal cut-off valve prevents excessive temperatures
  • Pressure sensitive gas cut-off system stops gas flow

 

The safety device type DS 1000 and DS 2000 offers additional protection from pressure shocks which arise, i.e. from flashbacks causing the gas flow to be interrupted. The green collar shows free flow and is covered by the reset collar. In order to continue working the user has to look for the cause of the flashback. Once the problem is corrected, the safety device is reset and work can be continued.

 

Datasheet download (PDF)

Details

Click for further informations.